Finnigan founded the scientific instruments division of electronic associates, inc. Actions and classified ads for thermo finnigan lcms and gcms systems, parts, circuit boards, and more on labx. We carry etp and mascom electron multipliers which are incorporated as original equipment in every major quadrupole and tof icp ms. Elemental scientific specializing in inert and high. Araujo b, h hintelmann, b dimock, mg almeida, ce rezende. A unique detection system in icp ms, combining a dual mode sem with a faraday detector, has been introduced with the finnigan element xr hr icp ms. Refurbished thermo finnigan lcq classic lc ms ms ion trap complete with the following.
We manufacture icp ms cones to the same exacting standards as all of our products and they are guaranteed to perform to your satisfaction. Thermal ionization mass spectrometry tims is used for very precise isotope ratio measurements. Pdf commercial development of hricpms, mcicpms and hrgdms. Stable isotope ratio measurements using the finnigan neptune multicollector icp ms claudia bouman thermo electron bremen 2 the neptune introduced 2000. Our worldclass electron multipliers feature longer lifetimes and enhanced sensitivity, for consistent and maximum performance. Research using the thermo finnigan element2 icp ms. Inductively coupled plasma mass spectrometry icp ms has grown rapidly. We have extensive shop facilities to perform the repair services listed below in addition to custom repair, modification and custom manufacture of any part you may need for your. Research using the thermo finnigan neptune mc icp ms. Equipped with an electrospray ionization esi source, the ltq boasts improved capacity and trapping efficiency, higher scan speed and increased sensitivity.
Nebulizers guaranteed to be compatible with your thermo finnigan icp ms. Register now and receive all the privileges associated with being a thermo electron, finnigan product user, including application reports and technical reports. Trace element speciation using icicpms complete inorganic elemental analysis solutions. Icpms detectors meinhard maintains inventory of your instruments electron multiplier. Pdf upb em zircao por lamcicpms no laboratorio paraiso. Stable isotope ratio measurements using the finnigan. The thermo scientific bremen finnigan element2 is the high resolution icp ms for routine productivity in your laboratory.
Meet the ever expanding application demands of geosciences and other disciplines that require highprecision isotope ratio measurements with thermo scientific neptune series high resolution multicollector icpms mc icp ms instrumentation. Dartlcq interface manual installing the dart on the lcq deca and classic models first, place the mass spectrometer in standby mode and remove the thermo finnigan source from the lcq mass spectrometer. Home page products icp icpms icpoes spares and accessories sorted by instrument manufacturer finnigan see thermo. With the element 2 there is always access to the most powerful. Thermo fisher scientific provides additional reference documents for the icap q mass spectrometer that are not part of the original operating instructions.
Atomic spectroscopy basics thermo fisher scientific. The thermo scientific neptune xt mc icp ms integrates estab. Dartlcq interface manual installing the dart on the lcq deca and classic models first, place the mass spectrometer in standby mode and remove the thermo finnigan source from the lcq mass. Icp inductively coupled plasma ms mass spectrometry. Such demanding analytical prerequisites often require the most sophisticated instrumentation, such as thermo electrons finnigan element 2. Glass expansion has over 20 years of experience in manufacturing icp ms sample introduction components and has earned a worldwide reputation for quality and reliability. Icp ms and organic for example, electrospray ionization esi ms is also possible, using a split flow from a single chromatographic device. Single collector, double focusing magnetic sector icp mass spectrometer thermo finnigan element 2 this instrument is used primarily for trace element ppb to ppm level analysis of solution samples and of solid samples by laser ablation, including uthpb isotopic dating of accessory minerals. The system incorporates the unique features of the triton analyzer and the the element2 plasma interface, which provide the basis for a uniquely powerful mc icp ms. Extended dynamic range high resolution icp ms introduction high resolution icp ms hr icp ms is widely used in geochemical applications for interferencefree multi. Pdf commercial development of hricpms, mcicpms and hr. Purified samples are thermally ionized by passing a current through a thin metal filament or. Complete refurbished icp inductively coupled plasma spectrometers and refurbished icp ms inductively coupled plasma mass spectroemters are available from major manufacturers including perkin elmer, thermo. The design of the finnigan neptune multicollector icp ms is based on the sum of our experience in multicollector technology and icp ms.
Cones, detectors, pump tubing and icp glassware compatible with all models of thermo finnigan icp ms instrumentation. Epond icp accessories are available for all types of icp instruments, but these tables of icp parts in pdf format are not exhaustive, so contact us for accessories for seiko, sii. Refurbished thermo trace dsq mass spectrometer complete with trace gc pn k27300000000010 and pc workstation. Isomist programmable temperature spray chamber glass. Media backgrounder high level information for journalists thermo fisher scientific in mass spectrometry much of science is devoted to answering two questions. Finnigantm element gd glow discharge mass spectrometer. Determination of chromium species using ion chromatography coupled to inductively coupled plasma mass spectrometry. Optimized laboratory software the software package is optimized for the needs of a routine laboratory, providing a simple to use interface to fully utilize the. Api stack, esi probe, edwards model e2m30 vacuum pump with hose, pentium iv pc, monitor, keyboard, mouse, and new finnigan. Examples of icp ms in molecular speciation are many and. The icptof is an inductively coupled plasma mass spectrometer icpms that couples the source and interface hardware of a thermo scientific icap rq to a. The finnigan element2 sector field icpms has been shown to provide the sensitivity, resistance to matrix, reliability and elemental selectivity to allow the determination of sub pg g1 concentrations in process chemicals used in the semiconductor industry.
I was so happy when i received those two repaired skimmers, shiny like brand new. Stable isotope ratio measurements using the finnigan neptune. Elements detectable by icp ms analysis perkinelmer. Guidelines for trouble shooting and maintenance of icp ms systems presented by dr. The finnigan neptune enables high precise stable isotope measurements due to stable mass bias e.
Finnigan element2 high performance high resolution icp ms principle the finnigan element2 is a double focusing magnetic sector. Mass spectrometry thermo finnigan ms repair this page scientific instrument services has been in the business of mass spectrometer service and repair since 1978. The mass spectrometry business of thermo fisher scientific inc. Benefits of coupling ic with icpms dionex corporation home. The presence of oxides and doublycharged ions in the plasma deteriorates the quantitative capability of icp ms in ultratrace analysis.
Inductively coupled plasma mass spectrometry or icpms is an analytical technique used for elemental determinations. Equipnet is the worlds leading provider of used mass spectrometers and numerous other types of preowned equipment. The single collector icpsfms element 2 thermo fisher scientific, waltham, ma, usa was operated in medium. Api stack, esi probe, edwards model e2m30 vacuum pump with hose, pentium iv pc, monitor, keyboard, mouse, and new finnigan xcalibur 2. The finnigan neptune is the first instrument capable of doing. Extended dynamic range high resolution icpms introduction high resolution icpms hricpms is widely used in geochemical applications for interferencefree multielemental determinations in complex sample matrices and for the measurement of precise isotope and elemental. This application report describes a variety of laicpms applications from different scientists to provide a. Epond supplies cones for all types of icpms instruments. Our product line consists of autosamplers, microflow pfa nebulizers, concentric nebulizers, apex desolvation nebulizers, pc3 peltier coolers, mp2 micro peristaltic pumps, fast solutions, application solutions and consumables. Iet refurbishes and certifies used icp and icp ms systems to meet original manufacturers oem specifications. Icpmass spectrometry the 30minute guide to icpms a worthy member of the inorganic analysis team for nearly 30 years, inductively coupled plasmamass spectrometry icpms has been gaining favor with laboratories around the world as the instrument of choice for performing trace metal analysis. The finnigan trace dsq is the new benchmark for single quadrupole gc ms systems. Since its commercialization in 1983, 3500 4000 icp ms systems. With ultrasensitive and reliable multielement analyses at tracelevel concentrations, theres no need for complicated sample preparation and method development.
Central scientific services provide access to flow cytometry, analytical and. Determination of ultratrace elements in photoresist solvents using the thermo scientific icap tqs icp ms. Calcium, strontium and barium biogeochemistry in a forested. Fisons instruments, and finnigan mat, then part of thermo. Pdf the evolution and applications of multicollector icpms. The finnigan neptune is a high precision multicollector icpms based on a proven icpsource element2 and an ultimate precision mcanalyzer triton. Commercial development of hricpms, mcicpms and hrgdms. Thermo fisher scientific legal entity reference guide issue date. The thermo scientific element 2 and element xr highresolution icp ms provide classleading elimination of interferences for the highest level of confidence. Our exclusive contracts with our clients yield a wide range of used mass spectrometers from a number of respected oems, including agilent, thermo. Robert emmet finnigan born may 27, 1927 is an american pioneer in the development of gas chromatographymass spectrometry equipment gc ms. Highprecision isotopic characterization of usgs reference. The ge is also required for cold plasma measurements massseparation the magnetic.
Mass spectrometry is the technology of choice used to answer these questions in a. In order to aid you in the selection of replacement parts for your instrument, the following part number cross reference chart can be used. Icicpms allows these industries to separate and quantify the different chemical forms. Media backgrounder high level information for journalists. Equipped with an electrospray ionization esi source, the ltq boasts improved. Scientific instrument services carries a wide selection of parts for all models of thermofinnigan mass spectrometers. New wave research esi nwr2 laser ablation system brochure pdf 1. Finnigan mat 253 stable isotope ratio mass spectrometer from thermo electron corporation the gold standard for isotope ratio ms highest sensitivity and linearity ampli. What robert thomas has assembled in this volume is 21 chapters that start with basic plasma concepts and icp ms instrument component descriptions and conclude with factors to be considered in selecting icp ms instruments. I am very satisfied with everything, especially the icp ms cones we recently purchased. Tfs has multiple pedigrees as the overall enterprise has been assembled by multiple acquisitions over the past 28 years. Pdf the evolution and applications of inductively coupled plasma mass spectrometry. Inductively coupled plasma mass spectrometry icpms has become the method of choice for. The use of an inductively coupled plasma source icp is the accepted and most.
Finnigan element 1, element 2, neptune archives accuscience. Plasma and interface the argon plasma ion source and sampling interface of the finnigan. The technique was commercially introduced in 1983 and has gained general acceptance in many types of laboratories. Elemental scientific specializes in inert and highsensitivity sample introduction systems for icp aes and icp ms elemental analysis. Msis coupled with multicollector inductively coupled plasma mass spectrometry mc icp ms. September 30, 2015 3 introduction the thermo fisher scientific legal entity reference guide is a map to the legal entities within thermo fisher. The analysis of trace elements in naphtha from thermo fisher accurate determination of copper, phosphorus and sulfur in ethanol from thermo fisher bioethanol from horiba jobin yvon applications of a temperature controlled spray chamber. A large range of elements can be detected using an icp ms, which are summarized in figure 1 below. Analytical west offers a full line of cones, detectors, pump tubing, icp glassware and rf supplies for all models of thermo finnigan icp ms instrumentation, including the elementelement2 and neptune models.
Finnigan neptune from thermo fisher scientific selectscience. The thermo finnigan ltq is a stateoftheart, segmented linear ion trap mass spectrometer. Extended dynamic range high resolution icp ms introduction high resolution icp ms hr icp ms is widely used in geochemical applications for interferencefree multielemental determinations in complex sample matrices and for the measurement of precise isotope and elemental. Sf icp ms element 2 from thermofinnigan this instrument is a double focusing magnetic sector field icp ms with the main following characteristics. In order to aid you in the selection of replacement parts for your instrument, the. Cpi international carries an advanced selection of continuous dynode electron multipliers for thermo finnigan used in determining presence of ion signals emitted by the mass analyzer of a mass spectrometer. Neptune series high resolution multicollector icpms. The ge is also required for cold plasma measurements. Identify organic and inorganic elements at ppm to subppt levels across the lab with our broad portfolio of icpms instrumentation. Mcicpms simplifies measurements normally made with thermal ionization mass spectrometry tims by. Icp lab department of earth science university of bergen.
Trace element speciation using icicpms complete inorganic. The parts lists linked to below in pdf format show most of them, but not all. Disadvantages of icp ms an outstanding icp aes instrument offers a longterm rsd of less than 1% compared to less than 4% for most icp ms systems. Thermo finnigan neptune multicollector icp ms publications. As shown in figure 1, icp ms consists of an ion source icp, a sampling interface, ion lens, a mass spectrophotometer and a detector.
Ppt icpms powerpoint presentation free to download. The thermo scientific element 2 and element xr high resolution icpms systems cover the mgl to sub pgl concentration rangemaking them. This addition significantly increases by at least three orders of magnitude the linear dynamic range, allowing count rates of over 1012 cps to be measured with the finnigan. The isotopic analyses were performed using a high resolution neptune thermo finnigan multicollector inductively coupled plasma mass spectrometer mc icp ms, equipped with an nd. The performance of single and multicollector icpms instruments. The abrf has two icpms instruments a thermo finnigan element2. Robert emmet finnigan born may 27, 1927 is an american pioneer in the development of gas chromatographymass spectrometry equipment gcms. Photonis 30140 multiplier 4870v for thermofinnigan sola. Spectro ms is a doublefocusing sector field icp ms inductively coupled plasma mass spectrometer, which measures mass range for inorganic mass spectrometry. Yag laser 266 nm camera translation stage argon inlet zoom lens impactor electrostatic precipitator calibration solution waste 90% 10% 20% 80% icp esa magnet argon inlet. Cpi international carries an advanced selection of continuous dynode electron multipliers for thermo finnigan used in determining presence of ion signals emitted by the mass analyzer of a mass. Thank you so much for repairing our 2 skimmer cones. Lato scientific glassworks currently manufactures and stocks most quartz and glass sample introduction consumables for icp and icpms. Practical guide to icp ms builds upon this published series.